Joe the Plumber, Feb 17, 2019. Severntrent Screwfix Select 600 long x 215 deep lintel at a guess, width 100? ask the SE and tell him not to be so lazy, Doesn't give a load rating, lazy again?Well weather was ok so cracked on outside. This goes in about 20 mm and then hits something and the drill can not make further progress. There will be guidelines on Birtley's website: what else do. The new opening will give an unsupported width of 1m. 8 m wide. A concrete lintel is by far the best way to go. However, our builder feels that this is overkill and a conventional H beam steel lintol is adequate. 99 Inc Vat Click & Collect Delivery OX Trade XL-10 Masonry Segmented Diamond Blade 300mm x 20mm (216HP) compare For Disc Cutters For General Masonry, Paving. Morning, I need to buy a 3. #2. Del boy 10, Jun 30, 2023. same width does nothingdifferent than bedding the. There was a curtain rail already nailed in (by the original builder ~40 years ago most likely), about 3 inches above the top of the window, so would anywhere above that point be ok? I read that most curtains are added about 6 inches above the window so would that be a safer bet? This is my first time doing any household DIY so many thanks!Hi, I need a lintel for over a ground floor door opening, I'm moving the opening about 350mm to the side, above is 1 and 12 light block and the floor joists for a bedroom, every room upstairs is stud wall so nothing other than the joists and blocks need support, the doorway is into the garage and was put in long after the house was built, and. Screwfix Community Forum. It’s all a bit awkward, as it’s where near where my water and electric mains come into the house and there is some legacy mess of the electric box and a bunch of cables etc. Galvanised, mild steel. Screw a wood trimer over it, and secure the new timber work to that. Found a company called watco that do a 2 part epoxy resin filler for. The mortar isn't holding the brickwork and lintel in place and cracks/parting of the two are gradually getting worse. A concrete lintel would suffice, the bottom course of bricks should be able to be drilled and taken out carefully then the new lintel inserted with compo to take up any gaps, you can then use a regular height firedoor. The ingoing edge nearing the ceiling hit a metal lintel some 3 foot or so into the garage. 99 Inc Vat. A lintel is a beam placed above openings like doors and windows to support the structural load. #1. Damn, not seen one of those for years. qwas123 Screwfix Select. You can then remove the infill below back to the opening and rebuild properly. Also it'll look odd having a lintel designed for a 2. For one row of breeze blocks and not loadbearing the header would need to be at least 4" high (and that means it would be about 4" high and about 5" wide). 6m and 1x for some french doors opposite wall to the garage door at 2. Fixings not included. Aaron Mcculla New Member. Just as important as the size of beam/lintel itself is to check that the lintel manufacturers will be designing the padstones to support each end of the lintel. And there is a wooden frame around the PVCu door frame. I’m widening the door frames in my house to 76cm ones. Chang New Member. 1. 8 m wide. I am building a concrete workshop which will have a doorway 1. Mix up like a regular powdered filler. Above the lintel is stone to the apex. And all the same to anyone else. You should be able to take that lintel out without any collapse, but it's your call, if you want to put in some props first. And besides as said, they are liable to restore. 2 = 2kN/m run of lintel so provided the lintel you are proposing quotes a Safe Working Load greater than this then all is good. The lintel above one of the upper floor windowes is looking less than great but I don't know how bad really. I would Get it surveyed. Thermal block has cracked diagonally starting from the end of the lintel, both towards the window opening and away from it, and has crumbled away in places. I have had lintels installed (wooden framed windows) builders thought no lintel needed back in ‘57. Catnic do a variety of heavy duty lintels, but at the top end of extreme duty are around £500-£600 for that span. #2. #2. There will be guidelines on Birtley's website: what else do you want ? stevie22, Mar 30, 2023. 2,The bricks should be on a bed not right on lintel (but only at the front of the lintel) 3,Depends on the condition of the lintel if it seems ok leave it in fit new window rake out and re point. View attachment 24992. Discussion in 'Builders' Talk' started by Sam Dingle. the other dimensions of it was 100*65, would this be strong enough. If you look at how the soldiers line up with the brickwork at the top of the frame, it doesn't look like there is. Obviously a decent HSS bit is essential 5 or 6mm (any recommedcations, I normally use dewalt) nice and slow as I. Cheers. If you can't move it, then I wouldn't get too worked up about the bearing, provided the brickwork above the lintel is properly keyed into the adjacent wall. Is an off the shelf ANG catnic lintel that can support uniform distribution of up to 7kN of weight enough to support a stone head going in above. Or hire a builder for a day. . #9. You should find a wooden lintol behind the arch, supporting the inside brickwork. My solution would be to fit a Catnic lintel above the stone lintel that is a good 150mm wider each side, this would relive the weight off the broken stone lintel. It’s flat and not L-shaped. Notnowvicar Screwfix Select. Do I need a new full length steel lintel bridging the whole length, inside and out. you are asking a question that can not be answered over the net, a little stupid me thinks. $172 11. You could use strappers to tie the blocks into. The lintel is above a first floor glazing opening which is floor to ceiling height and spans 3. My problem is a long concrete/stone lintel sitting above old metal window and ill fitting wooden door to workshop part of the building. The ones with the black squares is where the window will be going. downstairs bay window frame is cracking and was also fitted on to loose brick work which the company just repointed . Extra strong. 6 x 0. Don’t worry, it’s not especially difficult to do, however. they have had pvc windows put in 3 months ago and whoever did it put a lintel up because the made the window smaller but the lintel is only 3/4 the lenght of the window and above has been bricked up with paving. Ask a question. 2. It is perfectly ok to remove such a small amount from this section, it is done all the time. The builder has put a concrete brick in the coving of the RSJ but it is only under lapping the lintel by about an inch. Architect has advised to use a box 200 lintel, but what are my options. As above r2eally , when installing insulated cavity lintels do i need to cover with dpm and have weep holes, seems a bit hit and miss from info ive found so im not sure if you need todo this or not. Discussion in 'Builders' Talk' started by talk, Oct 19, 2008. We thought about putting a timber batten above the window on the inside wall, but the plaster and paint for the whole room is really uneven, so we're just trying to get some. 22 each (Inc. Use 75mm/3" screws, use a combination drill, a 6mm HSS twist drill bit to drill through the lintel, then a 6mm masonry bit or you may need a 6mm SDS bit with accompanying drill if the wall is concrete block as the normal masonry. Hello Everyone, We are currently renovating an old victorian property and we are wanting to make an alteration downstairs. Jord86 Screwfix Select. #2. The wall was a double skin wall, originally the external wall to the house and therefore load bearing. e. sospan Screwfix Select. If it was my own place I wouldn't mind as I would remember to take the key out before opening. You should be able to get an unequal 1/2" thick angle iron, perhaps 125mm high (it's an old house, so 5") and 50mm - 75mm deep (2 - 3"). Graham Swire New Member. Inset lintels and bed in place with mortar. As you can see there is a metal lintel above the doorway and it’s bedded into the wall I’m not removing and also laid on top of the lintel for the other doorway. I want to have this 4' hatch in a load bearing wall where the lintel is some 3' down from the ceiling. KBJ Active Member. 20mm at its most extreme and it’s pulled brickwork to the right the window, causing quite a lot of cracking. Live in a 1980s semi-detached house and during winter months we get excessive condensation on the recess wall above the bedroom window. Screwfix Community Forum. 5kn per sq metre. If you were to remove the plaster vertically, you will come across the actual lintel, which will be wider. Galvanised, mild steel. The wall plate is 2 brick courses above and it has also bowed, causing the. 2 = 2kN/m run of lintel so provided the lintel you are proposing quotes a Safe Working Load greater than this then all is good. I would Get it surveyed. Although bearing in minds the contract and expansion isn't that much. com. There will only be 2 courses of concrete blocks above them then a steel profile sheet roof. 60 metre garage out of 6 inch solids, the span of the door is 4. It is supposed to allow you to replace lintels and even put in steels without having to pin and prop. Garden room lintel. Get 10% off - View Offer. If they have been there for 15 years then I don't really see the problem. (1)Chop it out and build a brick arch over the actual fireplace, no lintel required, brick up sides as normal. Home Forums > Screwfix Community Forum > Builders' Talk > Upvc fascia board/lintel. You select your lintel based on loading it needs to resist Based on your description you will need a lintel that can take Area of a 45 degree triangular load above lintel = width x half the height = 1. Suits Screw Diameter. I thought padstones were supposed to be slate or metal! Mr. General mockupHi Guys I have a 100mm block wall internal load bearing which supports the joists only, all stud walls upstairs and all joist sit on the internal wall, my situation is I have an internal door & an opening next to the door divided by another 100mm wall at right angle which encases the oil boiler, total span off 2000mm but supported by a 4x3 wooden. Tags: lintel; shed roof; Jugs69 New Member. Timber frames were usually enough to support the brickwork with a 6x6 concrete lintel for the inner skin. I can’t find one anywhere though!. If it is ok to drill a little way into a concrete lintel, how come my combi drill and masonry bit aren’t making a. We would like to show you a description here but the site won’t allow us. so a 140x100 is 140 high as concrete lintels only span a single leaf of bricks. As above r2eally , when installing insulated cavity lintels do i need to cover with dpm and have weep holes, seems a bit hit and miss from info ive found so im not sure if you need todo this or not. In fact, on a door width size opening, you could almost eliminate the lintel once the wall above it was built and the mortar had set. Houses in the 60's and 70's were often built without a lintel on the outer skin. Acrow into place. 6m wide opening. As you found when the lintel bent, the wall did not follow (immediately!). Slow and steady. Think it's going to be fine for many years. One method of forming a lintel with soldiers and a cast insitu concrete inner lintel, was to fix wall ties into the joints of the soldiers and then cast the inner lintel. VAT) Supreme Prestressed Textured Concrete Lintel 100 x 100 x 1050 S10. These products are suitable for use on a variety of. Would anyone know if there is an issue and what I should expect to pay to get it sorted. Screwfix Community Forum. Support bracket for removal of internal chimney breast. 5 = 7kn/m run. OP you're overthinking. Hi can anyone suggest how to fit upvc fascia board to this sandstone lintel i was thinking of just no more nails some sort of wooden subframe I've got. I found this on my son's house, the old wooden windows had been replaced with PVC, their was a lintel on the inner leaf but none on the outer leaf. The existing lintels in the garage above the doors are box lintels. 1/ spread mortar along its top surface, use a spare akro to wind it up into place (not too hard tho) then backfill the 2 bearing surfaces on either end. S Builders New Member. Lintel and Cavity Tray The lintels are obviously different types. Is this possible?On this same wall there is also a bowing lintel above the window in the bottom right of the image which would need to be dealt with at the same time. 1m lintel as per my report to knock down a load bearing wall. The lintel is bowing slightly in the. For this type of work a SE will normally have specified the fixing method for the wallplate. ) stacked on top of each other he. The bricks are probably over-hanging the lintel edges so you can't see anything. Parts of cracked block have moved inwards into the room: the small piece I’ve labelled A has moved into the room by about 2mm, and the larger piece B has moved into the room by about. 17810219 UB @ 1100mm - Probably. 5kn. Or if you have some money rent one from a local rental place (cheaper than the chains). Apparently the top piece of concrete is the lintel and it's being supported by the concrete posts and the sill so nobody is prepared to take out the sides and sill. com. Yep and I feel it's happening to my house. Unless it's an unusually wide doorframe, don't bother with mechanical fixings in the head, once frame is fixed in position through the jambs, squirt expanding foam all around the back and head to close any gaps, insulate and further secure in position, it'll. sospan Screwfix Select. Wooden windows were replaced with uPVC around 8 years ago and from what I read that may have contributed to the problem. Anyone could help to explain their advantages and dis vantages. I would put a slightly longer lintel in that is toothed into the sides of the original builders opening. Bed it in nicely, and allow the mortar to set for. S Builders, Oct 12, 2008. CGN Screwfix Select. Then cutting out and removing old lintel/s, which will mean loosening course of bricks above. Product Length. As far as I can tell the lintel is just a relatively thin metal sheet. Hausfix, Sep 15, 2022. 1 - Get the lintel removed when the back door is bricked up as it will not be needed anyway after that? 2 - Leave the lintel but route the flue along the wall a bit before going though (perhaps the original) opening? Is that allowed by the regulations? 3 - Leave the lintel and somehow bore through it anyway? 4 - Open to suggestionsAny info would be great. At the least you WILL need a lintel. Drilling into a lintel seems like a bad idea, what with it holding up the wall and everything. Wayners Screwfix Select. stuart44 Screwfix Select. FREE next day delivery available, free collection in 1. I am looking to put a concrete lintel above this which will support a single coarse of blocks and the flat roof. Such as flat steel (on the outside wall) inserted all the way underneath the present lintels, thereby bridging the centre part - with the new window underneath to add additional support. 101mm Working Length. Fillers and Putty are used to fill or seal holes, cracks, or gaps prior to further decorating. This goes in about 20 mm and then hits something and the drill can not make further progress. 65 could work dependant on the situation so it might be worth a number crunch instead of reaching for the breaker. Hi Jitender. Area of load = 41m2. You won't lose any internal floor area and having the thermal mass (ie brick wall and concrete slab) inside the insulation will make a big difference. Even composite ones with a single bar in the centre or neutral plane can have a rough top as a key for the brickwork. Joe1985 Guest. Hi all, I have two non load bearing concrete blockwork walls. The builder cleaned the bricks and mortar around the new lintels with brick cleaner to help disguise the work done on the house. Home Forums > Screwfix Community Forum > Builders' Talk > Lintel? Discussion in 'Builders' Talk' started by ir, Apr 15, 2010. The job was due to be done within a month but various delays meant that didn’t happen. More Info. So ref your other post about the steel, it has to carry. Hi gregz0012, yes you should be ok to remove the recent brickwork, years ago they built what they called a "builders opening" for fireplaces, and whatever form of fire was put in afterwards, they also used to put timber lintols in, so that arch was put there to relieve the weight of the chimney breast off the timber lintol, in fact i think they were/are called. The span is 2300mm and there was a prestressed concrete lintel with a span of 2700mm. Nick058162 New Member. com. 2/ mortar up the 2 end bearings drop the lintel onto these then backfill the upper surface. Home Forums > Screwfix Community Forum > Builders' Talk > Lintels. Discussion in. 4 metres. stuart44 Screwfix Select. I’ve got a solid brick wall at around 350mm thickness with an opening of 2. PFC Plates - Galvanised Steel. As you can see there are 2 damaged aerated blocks on the inner leaf and one damaged on the outer leaf underneath the 150mm bearing of the lintel. Choose from top trade brands. Take your time and keep checking the. The interior already has a concrete lintel in. One opening will need to support three floor joists at midspan. Not impressive work by the builder. Went to the merchants for a lintel yesterday, the bloke behind the counter said " how long do you want it ?" well . Step 2 - install lintel and place props and strongboys wait 5 days for mortar to set. 2m. Write a review. 9 KB Views: 48. A lintel, whether concrete,metal should have a minimum bearing of 150mm bearing each end,now't wrong with a lintel having a bit more support each end. CLEARANCE. Test one out before drilling all the holes. I have no idea how to overcome that as the brackets will not hold up when. CGN, Jan 16, 2022. BuilderMCR, Feb 12, 2014. To prevent corbonation it must be vibrated and the mix. 2m. Pack in mortar tightly all around. Ian Dingwall New Member. It might be possible to put the doors in with no lintel IF the door header was thick enough. I took the bricks out and put them back in (with the help of a bricky. The other (identical) opening has to support an existing 250x250 steel beam (at 90 degrees) that is currently supporting an upstairs wall which in turn supports the wall plate which has the roof on it and. Even allowing for the dodgy brickwork/bits of. Buy Builders Metalwork at Screwfix. I intend to replace the conservatory, but just find that the mortar above the lintel has cracks causing like 3-5mm horizontal gap. Notnowvicar, Feb 23, 2023. I have a couple rotten joists by the front door (hall) and a rotten lintel above the door on the lower ground floor. The dimensions of the existing wooden lintel is: Width 1100mm. Option 2 - I replace the cracked concrete lintel with a new concrete lintel and remove the RSJ. Above the garage door will be cladded with cement board rather than be load bearing like blocks. Nowadays they are often pre-stressed in the neutral plane. I myself would rebuild the left pier, right could be repaired, difficult to be accurate looking at a photo & not actually being there. #3. You've done structural work so BC should have an involvement. The lintel more than likely would have been a separate timber lintel, you can still see the bearings where it sat or it could have been part of the frame with 4x2 horns extending into the brickwork. What lintel is on the outer skin? Or is it an arch. The centre of the hole will be 120mm above the top face of the lintel. I’m widening the door frames in my house to 76cm ones. Secure and support timber & masonry structures safely & professionally. Its plasterboard initially but then a lintel presumably. Screwfix Community Forum. Infill insulation and plasterboard. however now ive removed the doors ive found theyve used a timber lintel (it is a load bearing wall), the width of the opening is 3. Is it ok to drill into a concrete lintel or should I stick a wooden plinth on top and use that to hang the blind? 2. Deleted member 33931, Mar 23, 2016. Discussion in 'Builders' Talk' started by Pawr, Apr 29, 2017. 0. Without doing research into current regulations, based on my experience alone I’d suggest you will definitely need a 600mm lintel and with a cavity tray and weep vents above. Mr. Pick a joint line and follow that. Discussion in ' Builders' Talk ' started by Alhashed, 4 minutes ago . 6 mm. A window company I've used before gave me a reasonable quote for the doors, but they've given me an estimate of £1,500 - £2k to put a lintel in. Prestressed concrete lintels are an excellent solution in providing economical and robust masonry support over door. The house is 1930s brick and original windows have steel frames set into a wooden frame with a soldier course above. What lintel is on the outer skin? Or is it an arch. . jpeg File size: 601. 8m) Rather more than a rotten piece of timber strength of not much more than 0kN/m,. 6kg required. Typically made from galvanized steel and designed to be installed quickly and safely. sospan, Oct 28, 2015. Roughly speaking do you think a H. The opening's been narrowed and shortened at some point in the past (I get the feeling this was done by a previous owner rather than a professional). Use the smallest bit to drill a pilot hole and work your way up to your required size. 5 the value that the triangular area of brickwork above the opening actually imparts upon it so structurally wise its well ok as the fact that its. May be tricker if you have a 'soldier' brick. 4 metres. I have exposed the internal side of the concrete lintel above my lounge window as I was adding insulation behind the plasterboard. The Stressline fair faced prestressed concrete lintel, 100mm wide x 215mm high, 2. Fixings not included. 3 lintels in total. 99 Inc Vat Click & Collect Delivery OX Trade XL-10 Masonry Segmented Diamond Blade 300mm x 20mm (216HP) compare For Disc Cutters For General Masonry, Paving Bricks, Hard Stones, Kerbs & Lintels Sintered £27. Make up some platforms on trestles or scaffold so you can do the lift in stages. I've fit new french doors, uPVC ones. The both garages of both houses are in the mid part. But guess main question is does it matter, is there a gap above where the frame of the doors will go, with a metal lintel like that was expecting it to be dead flat especially as second storey still to go: Easier to see in this picture, if I put a long level over at front then rocks on the bend although quite hard to see in picture:Order online at Screwfix. . The bricks are 102mm, the lintol shelf is 96mm. There is a very small area of the wooden lintel that seems damp and soft (see the left of. I am using an SDS drill with 5mm drill bit. Â, Feb 21, 2006. Afternoon all I’m about to put a single skin lintel in above a window before putting patio doors in. two foot wide is mentioned - so 2 props either side of the opening, needles through, with 2 more on the other side of the wall taking the other end of the support member/needle - somewhat simillar to the below. Have you fixed the leak above them, because if not, that's. Discussion in 'Builders' Talk' started by foxer fc, Sep 9, 2023. Design will show that a 65mm p/s concrete lintel is ok - cost about £10. Footings and load calculations will be required. What lintel could I put in and how could it be fixed? My only though was to bolt a 102 H column to each of the existing end columns and then span it with a better lintel. #3. Home Forums > Screwfix Community Forum > Builders' Talk > Lintel. Most BCO are happy with this. So, it serve important an fuction & you can't just put a opening in on the ground. I have an idea to use steel angle brackets to attach to the lintels and shed, but what would be a good way to attach the brackets to the top of the lintel, it will need to. One method of forming a lintel with soldiers and a cast insitu concrete inner lintel, was to fix wall ties into the joints of the soldiers and then cast the inner lintel. I thought padstones were supposed to be slate or metal! Mr. With concrete up top, a prestressed concrete lintel would not look out of place. I was thinking about putting a bit of timber although that would need brackets (i was thinking of a wooden block) on the end verticals to support it and worried it might all be a bit ugly/bulky. Remove loose paint and wire brush lintel, then dust down. stevie22 Screwfix Select. This would then tie the 2 together. 8m. However, there is no bowing of the lintel above the window or any issues with the external masonry. The rules as I understand them is a lintel up to 1200mm can have a 100mm bearing, longer than that and it's 150mm min. 5m rule. It may have been cast in place and bars have gone rusty plus water got in it so it's cracked. #19. Morning, I need to buy a. Screwfix Community Forum. Doesn't look like a lintel is in place on the external skin brickwork. Catnic do a variety of heavy duty lintels, but at the top end of extreme duty are around £500-£600 for that span. D. They are refusing to pay saying wrong lintel was put in and waiting for structural engineer to do his report. S Builders New Member. Then finish with mortar and leave the Acro's in overnight. You could almost certainly neatly cut out the horizontal row of bricks immediately above your proposed door frame using your saw so's you can slip your lintel straight in (with a min 150mm overlap at each end - I think. tomplum Active Member. The ‘crack’ in the lintel is actually just the decorative style. I would have expected to use accro props with strong bows min of 3 for the big one. neilbick New Member. So the lintel manufacturers are more likely the ones spreading such tosh. The upstairs ones you cannot even see above the solider bricks before you hit the roof. Two questions: 1. One wall I am removing between the kitchen and living room. 30 day money back guarantee. Even allowing for the dodgy brickwork/bits of. Maybe concrete padstones will be required here. = 509. Joe the Plumber Screwfix Select. Galintel 85mm x 7mm x 1400mm Galvanised Flat Lintel Flat Bar (0) $47. there are 4 catnic lintels that will do a solic 9 inch wall, all with various strengths I have now found out. When it is cold it is contracted leaving small gaps between the brick and the pointing for which rainwater can get into, when it is warm it is flushed with the bricks. Chang New Member. 3m span is on your lintel that is 1. Want some proper acrows supporting that lot, also lintel need a minimum bearing of 150mm each end. You could almost certainly neatly cut out the horizontal row of bricks immediately above your proposed door frame using your saw so's you can slip your lintel straight in (with a min 150mm overlap at each end - I think. Having the lintel more or less touching the frame isn't a problem, it just shows they measured an manufactured the windows accurately as you don't want big gaps. I intend to replace the conservatory, but just find that the mortar above the lintel has cracks causing like 3-5mm horizontal gap. I was thinking of putting 2 concrete lintels in, one for each skin of the wall to make life easier, theres 5 courses of brickwork above my proposed lintels with a tiled roof. I've taken the chimney out in my house and whilst I was removing it found it was partly being supported by what I can only describe as a concrete lintel that is inserted into the party wall, presumably for counter leverage. Danblez New Member. I can't use battens side or face fix. Available in a variety of options. 60 metre garage out of 6 inch solids, the span of the door is 4.